HEX
Server: LiteSpeed
System: Linux kapuas.iixcp.rumahweb.net 5.14.0-427.42.1.el9_4.x86_64 #1 SMP PREEMPT_DYNAMIC Fri Nov 1 14:58:02 EDT 2024 x86_64
User: mirz4654 (1666)
PHP: 8.1.33
Disabled: system,exec,escapeshellarg,escapeshellcmd,passthru,proc_close,proc_get_status,proc_nice,proc_open,proc_terminate,shell_exec,popen,pclose,dl,pfsockopen,leak,apache_child_terminate,posix_kill,posix_mkfifo,posix_setsid,posix_setuid,posix_setpgid,ini_alter,show_source,define_syslog_variables,symlink,syslog,openlog,openlog,closelog,ocinumcols,listen,chgrp,apache_note,apache_setenv,debugger_on,debugger_off,ftp_exec,dll,ftp,myshellexec,socket_bind,mail,posix_getwpuid
Upload Files
File: //usr/lib/dracut/modules.d/98dracut-systemd/dracut-shutdown.service.8.asc
DRACUT-SHUTDOWN.SERVICE(8)
===========================
:doctype: manpage
:man source:   dracut
:man manual:   dracut

NAME
----
dracut-shutdown.service - unpack the initramfs to /run/initramfs

SYNOPSIS
--------
dracut-shutdown.service

DESCRIPTION
-----------
This service unpacks the initramfs image to /run/initramfs.
systemd pivots into /run/initramfs at shutdown, so the root filesystem
can be safely unmounted.

The following steps are executed during a shutdown:

* systemd switches to the shutdown.target
* systemd starts /lib/systemd/system/shutdown.target.wants/dracut-shutdown.service
* dracut-shutdown.service executes /usr/lib/dracut/dracut-initramfs-restore which unpacks the initramfs to /run/initramfs
* systemd finishes shutdown.target
* systemd kills all processes
* systemd tries to unmount everything and mounts the remaining read-only
* systemd checks, if there is a /run/initramfs/shutdown executable
* if yes, it does a pivot_root to /run/initramfs and executes ./shutdown. The old root is then mounted on /oldroot. /usr/lib/dracut/modules.d/99shutdown/shutdown.sh is the shutdown executable.
* shutdown will try to umount every /oldroot mount and calls the various shutdown hooks from the dracut modules 

This ensures, that all devices are disassembled and unmounted cleanly.

To debug the shutdown process, you can get a shell in the shutdown procedure
by injecting "rd.break=pre-shutdown rd.shell" or "rd.break=shutdown rd.shell".
----
# mkdir -p /run/initramfs/etc/cmdline.d
# echo "rd.break=pre-shutdown rd.shell" > /run/initramfs/etc/cmdline.d/debug.conf
# touch /run/initramfs/.need_shutdown
----

In case the unpack of the initramfs fails, dracut-shutdown-onfailure.service
executes to make sure switch root doesn't happen, since it would result in
switching to an incomplete initramfs.

AUTHORS
-------
Harald Hoyer

SEE ALSO
--------
*dracut*(8)