File: //proc/self/root/usr/lib/netdata/conf.d/go.d/snmp.profiles/default/cisco-firepower.yaml
extends:
- _system-base.yaml
- _std-if-mib.yaml
- _cisco-metadata.yaml
# This profile does not import cisco.yaml on purpose
metadata:
device:
fields:
type:
value: Firewall/Firepower
vendor:
value: Cisco
sysobjectid:
- 1.3.6.1.4.1.9.1.2404 # Cisco FPR 2110td
- 1.3.6.1.4.1.9.1.2405 # Cisco FPR 2120td
- 1.3.6.1.4.1.9.1.2406 # Cisco FPR 2130td
- 1.3.6.1.4.1.9.1.2407 # Cisco FPR 2140td
- 1.3.6.1.4.1.9.1.2778 # Cisco FPR 4125 K9
- 1.3.6.1.4.1.9.1.2292 # Cisco FPR 4150 K9
# Following sysObjectID requires more investigation to be certain if we should include it:
# - 1.3.6.1.4.1.9.12.3.1.3.1788 # Cisco FPR 4120
metrics:
- MIB: CISCO-PROCESS-MIB
table:
OID: 1.3.6.1.4.1.9.9.109.1.1.1
name: cpmCPUTotalTable
symbols:
- OID: 1.3.6.1.4.1.9.9.109.1.1.1.1.7 # cpmCPUTotal1minRev
name: cpu.usage
chart_meta:
description: The current CPU utilization
family: 'System/CPU/Usage'
unit: "%"
metric_tags:
- tag: cpu_index
index: 1 # cpmCPUTotalIndex
- MIB: CISCO-FIREPOWER-SM-MIB
table:
OID: 1.3.6.1.4.1.9.9.826.1.71.20
name: cfprSmMonitorTable
symbols:
- OID: 1.3.6.1.4.1.9.9.826.1.71.20.1.21 # cfprSmMonitorMemFree
name: memory.free
chart_meta:
description: Memory free
family: 'System/Memory/Free'
unit: "By"
- OID: 1.3.6.1.4.1.9.9.826.1.71.20.1.23 # cfprSmMonitorMemUsed
name: memory.used
chart_meta:
description: Memory used
family: 'System/Memory/Used'
unit: "By"
metric_tags:
- tag: mem_index
index: 1 # cfprSmMonitorInstanceId
- MIB: CISCO-FIREPOWER-SM-MIB
table:
OID: 1.3.6.1.4.1.9.9.826.1.71.20
name: cfprSmMonitorTable
symbols:
- OID: 1.3.6.1.4.1.9.9.826.1.71.20.1.17
name: cfprSmMonitorDataDiskAvailable
chart_meta:
description: Data disk available
family: 'System/Disk/Data/Available'
unit: "By"
scale_factor: 1024
- OID: 1.3.6.1.4.1.9.9.826.1.71.20.1.18
name: cfprSmMonitorDataDiskTotal
chart_meta:
description: Data disk total
family: 'System/Disk/Data/Total'
unit: "By"
scale_factor: 1024
metric_tags:
- tag: cfpr_sm_monitor_dn
symbol:
OID: 1.3.6.1.4.1.9.9.826.1.71.20.1.2
name: cfprSmMonitorDn
- MIB: CISCO-FIREPOWER-EQUIPMENT-MIB
table:
OID: 1.3.6.1.4.1.9.9.826.1.20.34
name: cfprEquipmentFanTable
symbols:
- OID: 1.3.6.1.4.1.9.9.826.1.20.34.1.10
name: cfprEquipmentFanOperState
chart_meta:
description: Equipment/Fans
family: 'Hardware/Fan/Operational/Status'
unit: "{status}"
mapping:
0: unknown
1: operable
2: inoperable
3: degraded
4: powered_off
5: power_problem
6: removed
7: voltage_problem
8: thermal_problem
9: performance_problem
10: accessibility_problem
11: identity_unestablishable
12: bios_post_timeout
13: disabled
14: malformed_fru
51: fabric_conn_problem
52: fabric_unsupported_conn
81: config
82: equipment_problem
83: decomissioning
84: chassis_limit_exceeded
100: not_supported
101: discovery
102: discovery_failed
103: identify
104: post_failure
105: upgrade_problem
106: peer_comm_problem
107: auto_upgrade
108: link_activate_blocked
metric_tags:
- tag: cfpr_equipment_fan_dn
symbol:
OID: 1.3.6.1.4.1.9.9.826.1.20.34.1.2
name: cfprEquipmentFanDn
- MIB: CISCO-FIREPOWER-EQUIPMENT-MIB
table:
OID: 1.3.6.1.4.1.9.9.826.1.20.109
name: cfprEquipmentPsuTable
symbols:
- OID: 1.3.6.1.4.1.9.9.826.1.20.109.1.13
name: cfprEquipmentPsuPower
chart_meta:
description: Psu power state
family: 'Hardware/PowerSupply/Power/Status'
unit: "{status}"
mapping:
0: unknown
1: on
2: test
3: off
4: online
5: offline
6: offduty
7: degraded
8: power_save
9: error
10: ok
11: failed
12: oir_failed
13: oir_invalid
100: not_supported
metric_tags:
- tag: cfpr_equipment_psu_dn
symbol:
OID: 1.3.6.1.4.1.9.9.826.1.20.109.1.2
name: cfprEquipmentPsuDn