File: //proc/self/root/usr/lib/netdata/conf.d/go.d/snmp.profiles/default/_dell-rac.yaml
# Provide metrics that can be found in Dell devices that are or contain DRAC components
# 1. DELL-RAC-MIB
# https://mibbrowser.online/mibdb_search.php?mib=DELL-RAC-MIB
# https://github.com/librenms/librenms/blob/master/mibs/dell/DELL-RAC-MIB
# 2. IDRAC-MIB-SMIv2
# https://mibbrowser.online/mibdb_search.php?mib=IDRAC-MIB-SMIv2
# https://github.com/librenms/librenms/blob/master/mibs/dell/IDRAC-MIB-SMIv2
metrics:
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.200.10
name: systemStateTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.4
name: systemStateChassisStatus
chart_meta:
family: 'Hardware/Chassis/Status'
description: Chassis status of the system state
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.6
name: systemStatePowerUnitStatusRedundancy
chart_meta:
family: 'Hardware/Power/Unit/Redundancy/Status'
description: Power unit status redundancy of the system state
unit: "{status}"
mapping:
1: other
2: unknown
3: full
4: degraded
5: lost
6: not_redundant
7: redundancy_offline
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.9
name: systemStatePowerSupplyStatusCombined
chart_meta:
family: 'Hardware/Power/Supply/Status/Combined'
description: Combined power supply status of the system state
unit: "{state}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.15
name: systemStateAmperageStatusCombined
chart_meta:
family: 'Hardware/Sensor/Amperage/Status/Combined'
description: Combined amperage status of the system state
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.18
name: systemStateCoolingUnitStatusRedundancy
chart_meta:
family: 'Hardware/Cooling/Unit/Redundancy/Status'
description: Cooling unit status redundancy of the system state
unit: "{status}"
mapping:
1: other
2: unknown
3: full
4: degraded
5: lost
6: not_redundant
7: redundancy_offline
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.21
name: systemStateCoolingDeviceStatusCombined
chart_meta:
family: 'Hardware/Cooling/Device/Status/Combined'
description: Combined cooling device status of the system state
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.24
name: systemStateTemperatureStatusCombined
chart_meta:
family: 'Hardware/Sensor/Temperature/Status/Combined'
description: Combined temperature status of the system state
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.27
name: systemStateMemoryDeviceStatusCombined
chart_meta:
family: 'Hardware/Memory/Device/Status/Combined'
description: Combined memory device status of the system state
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.30
name: systemStateChassisIntrusionStatusCombined
chart_meta:
family: 'Hardware/Chassis/Intrusion/Status/Combined'
description: Combined chassis intrusion status of the system state
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.42
name: systemStatePowerUnitStatusCombined
chart_meta:
family: 'Hardware/Power/Unit/Status/Combined'
description: Combined power unit status of the system state
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.44
name: systemStateCoolingUnitStatusCombined
chart_meta:
family: 'Hardware/Cooling/Unit/Status/Combined'
description: Combined cooling unit status of the system state
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.50
name: systemStateProcessorDeviceStatusCombined
chart_meta:
family: 'Hardware/Processor/Device/Status/Combined'
description: Combined processor device status of the system state
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.63
name: systemStateTemperatureStatisticsStatusCombined
chart_meta:
family: 'Hardware/Sensor/Temperature/Statistics/Status/Combined'
description: Combined temperature statistics status of the system state
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.200.10.1.1
name: systemStatechassisIndex
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4
name: physicalDiskTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4
name: physicalDiskState
chart_meta:
family: 'Hardware/Disk/Physical/State'
description: State of the physical disk
unit: "{status}"
mapping:
1: unknown
2: ready
3: online
4: foreign
5: offline
6: blocked
7: failed
8: nonraid
9: removed
10: readonly
- OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11
name: physicalDiskCapacityInMB
scale_factor: 1048576
chart_meta:
family: 'Hardware/Disk/Physical/Capacity'
description: Capacity of the physical disk in megabytes
unit: "By"
- OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.17
name: physicalDiskUsedSpaceInMB
scale_factor: 1048576
chart_meta:
family: 'Hardware/Disk/Physical/Used'
description: Used space of the physical disk in megabytes
unit: "By"
- OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.19
name: physicalDiskFreeSpaceInMB
scale_factor: 1048576
chart_meta:
family: 'Hardware/Disk/Physical/Free'
description: Free space of the physical disk in megabytes
unit: "By"
metric_tags:
- tag: disk_number
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1
name: physicalDiskNumber
- tag: disk_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2
name: physicalDiskName
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9
name: enclosurePowerSupplyTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.4
name: enclosurePowerSupplyState
chart_meta:
family: 'Hardware/Enclosure/PowerSupply/State'
description: State of the enclosure power supply
unit: "{status}"
mapping:
1: unknown
2: ready
3: failed
4: missing
5: degraded
metric_tags:
- tag: supply_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2
name: enclosurePowerSupplyName
- tag: enclosure_power_supply_number
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1
name: enclosurePowerSupplyNumber
- tag: enclosure_power_supply_fqdd
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.15
name: enclosurePowerSupplyFQDD
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15
name: batteryTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4
name: batteryState
chart_meta:
family: 'Hardware/Battery/State'
description: State of the battery
unit: "{status}"
mapping:
1: unknown
2: ready
3: failed
4: degraded
5: missing
6: charging
7: below_threshold
metric_tags:
- tag: battery_fqdd
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.20
name: batteryFQDD
- tag: battery_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21
name: batteryDisplayName
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1
name: controllerTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.37
name: controllerRollUpStatus
chart_meta:
family: 'Hardware/Controller/Status/RollUp'
description: Roll up status of the controller
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
metric_tags:
- tag: controller_number
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.1
name: controllerNumber
- tag: controller_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2
name: controllerName
- tag: controller_pci_slot
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.42
name: controllerPCISlot
- tag: controller_fqdd
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.78
name: controllerFQDD
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.80
name: pCIDeviceTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.5
name: pCIDeviceStatus
chart_meta:
family: 'Hardware/PCIDevice/Status'
description: Status of the PCI device
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
metric_tags:
- tag: device_descr_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.9
name: pCIDeviceDescriptionName
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.80.1.1
name: pCIDevicechassisIndex
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.1200.10
name: systemSlotTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.5
name: systemSlotStatus
chart_meta:
family: 'Hardware/Slot/Status'
description: Status of the system slot
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
metric_tags:
- tag: slot_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.8
name: systemSlotSlotExternalSlotName
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1200.10.1.1
name: systemSlotchassisIndex
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.90
name: networkDeviceTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.3
name: networkDeviceStatus
chart_meta:
family: 'Network/Device/Status'
description: Status of the network device
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.1
name: networkDeviceChassisIndex
- tag: mac_addr
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.16
name: networkDevicePermanentMACAddress
- tag: device_fqdd
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.90.1.30
name: networkDeviceFQDD
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.300.50
name: systemBIOSTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.300.50.1.5
name: systemBIOSStatus
chart_meta:
family: 'System/BIOS/Status'
description: Status of the system BIOS
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.300.50.1.1
name: systemBIOSchassisIndex
- tag: system_bios_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.300.50.1.2
name: systemBIOSIndex
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.300.70
name: intrusionTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.300.70.1.5
name: intrusionStatus
chart_meta:
family: 'Hardware/Intrusion/Status'
description: Status of the intrusion
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.300.70.1.6
name: intrusionReading
chart_meta:
family: 'Hardware/Intrusion/Reading'
description: Reading of the intrusion
unit: "{reading}"
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.300.70.1.1
name: intrusionchassisIndex
- tag: intrusion_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.300.70.1.2
name: intrusionIndex
- tag: intrusion_location_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.300.70.1.8
name: intrusionLocationName
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.600.12
name: powerSupplyTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.600.12.1.6
name: powerSupplyOutputWatts
chart_meta:
family: 'Hardware/PowerSupply/Output/Power'
description: Output power of the power supply in watts
unit: "W"
- OID: 1.3.6.1.4.1.674.10892.5.4.600.12.1.9
name: powerSupplyMaximumInputVoltage
chart_meta:
family: 'Hardware/PowerSupply/Input/Voltage/Maximum'
description: Maximum input voltage of the power supply
unit: "V"
- OID: 1.3.6.1.4.1.674.10892.5.4.600.12.1.16
name: powerSupplyCurrentInputVoltage
chart_meta:
family: 'Hardware/PowerSupply/Input/Voltage/Current'
description: Current input voltage of the power supply
unit: "V"
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.12.1.1
name: powerSupplychassisIndex
- tag: power_supply_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.12.1.2
name: powerSupplyIndex
- tag: power_supply_fqdd
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.12.1.15
name: powerSupplyFQDD
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.600.30
name: amperageProbeTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.5
name: amperageProbeStatus
chart_meta:
family: 'Hardware/Sensor/Amperage/Status'
description: Status of the amperage probe
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical_upper
5: critical_upper
6: non_recoverable_upper
7: non_critical_lower
8: critical_lower
9: non_recoverable_lower
10: failed
- OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.6
name: amperageProbeReading
chart_meta:
family: 'Hardware/Sensor/Amperage/Value'
description: Reading of the amperage probe in amperes
unit: "A"
metric_tags:
- tag: probe_type
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.7
name: amperageProbeType
mapping:
1: other
2: unknown
3: 1point5_volt # 1.5 volt
4: 3point3_volt # 3.3 volt
5: 5_volt # 5 volt
6: minus5_volt # -5 volt
7: 12_volt # 12 volt
8: minus12_volt # -12 volt
9: io
10: core
11: flea
12: battery
13: terminator
14: 2point5_volt # 2.5 volt
15: gtl
16: discrete
23: power_supply_amps
24: power_supply_watts
25: system_amps
26: system_watts
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.1
name: amperageProbechassisIndex
- tag: amperage_probe_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.30.1.2
name: amperageProbeIndex
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.600.60
name: powerUsageTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.600.60.1.5
name: powerUsageStatus
chart_meta:
family: 'System/Power/Usage/Status'
description: Status of the power usage
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.60.1.1
name: powerUsageChassisIndex
- tag: power_usage_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.60.1.2
name: powerUsageIndex
- tag: power_usage_entity_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.60.1.6
name: powerUsageEntityName
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.600.20
name: voltageProbeTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.5
name: voltageProbeStatus
chart_meta:
family: 'Hardware/Sensor/Voltage/Status'
description: Status of the voltage probe
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical_upper
5: critical_upper
6: non_recoverable_upper
7: non_critical_lower
8: critical_lower
9: non_recoverable_lower
10: failed
- OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.6
name: voltageProbeReading
chart_meta:
family: 'Hardware/Sensor/Voltage/Value'
description: Reading of the voltage probe in volts
unit: "V"
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.1
name: voltageProbechassisIndex
- tag: voltage_probe_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.2
name: voltageProbeIndex
- tag: probe_type
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.20.1.7
name: voltageProbeType
mapping:
1: other
2: unknown
3: 1point5_volt # 1.5 volt
4: 3point3_volt # 3.3 volt
5: 5_volt # 5 volt
6: minus5_volt # -5 volt
7: 12_volt # 12 volt
8: minus12_volt # -12 volt
9: io
10: core
11: flea
12: battery
13: terminator
14: 2point5_volt # 2.5 volt
15: gtl
16: discrete
17: generic_discrete
18: ps_voltage
19: memory_status
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.600.50
name: systemBatteryTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.600.50.1.5
name: systemBatteryStatus
chart_meta:
family: 'Hardware/Battery/System/Status'
description: Status of the system battery
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.600.50.1.6
name: systemBatteryReading
chart_meta:
family: 'Hardware/Battery/System/Reading'
description: Reading of the system battery
unit: "{reading}"
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.50.1.1
name: systemBatteryChassisIndex
- tag: system_battery_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.50.1.2
name: systemBatteryIndex
- tag: system_battery_location_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.600.50.1.7
name: systemBatteryLocationName
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.700.10
name: coolingUnitTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.700.10.1.5
name: coolingUnitRedundancyStatus
chart_meta:
family: 'Hardware/Cooling/Unit/Redundancy/Status'
description: Redundancy status of the cooling unit
unit: "{status}"
mapping:
1: other
2: unknown
3: full
4: degraded
5: lost
6: not_redundant
7: redundancy_offline
- OID: 1.3.6.1.4.1.674.10892.5.4.700.10.1.8
name: coolingUnitStatus
chart_meta:
family: 'Hardware/Cooling/Unit/Status'
description: Status of the cooling unit
unit: "{status}"
mapping:
1: other
2: unknown
3: full
4: degraded
5: lost
6: not_redundant
7: redundancy_offline
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.700.10.1.1
name: coolingUnitchassisIndex
- tag: cooling_unit_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.700.10.1.2
name: coolingUnitIndex
- tag: cooling_unit_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.700.10.1.7
name: coolingUnitName
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.700.12
name: coolingDeviceTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.5
name: coolingDeviceStatus
chart_meta:
family: 'Hardware/Cooling/Device/Status'
description: Status of the cooling device
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical_upper
5: critical_upper
6: non_recoverable_upper
7: non_critical_lower
8: critical_lower
9: non_recoverable_lower
10: failed
- OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.6
name: coolingDeviceReading
chart_meta:
family: 'Hardware/Cooling/Device/Speed'
description: Reading of the cooling device
unit: "{revolution}/min"
- OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.18
name: coolingDeviceDiscreteReading
chart_meta:
family: 'Hardware/Cooling/Device/DiscreteReading'
description: Discrete reading of the cooling device
unit: "{reading}"
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.1
name: coolingDevicechassisIndex
- tag: cooling_device_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.2
name: coolingDeviceIndex
- tag: cooling_device_type
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.7
name: coolingDeviceType
mapping:
1: other
2: unknown
3: a_fan
4: a_blower
5: a_chip_fan
6: a_cabinet_fan
7: a_power_supply_fan
8: a_heat_pipe
9: refrigeration
10: active_cooling
11: passive_cooling
- tag: cooling_device_location_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.8
name: coolingDeviceLocationName
- tag: cooling_device_fqdd
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.700.12.1.19
name: coolingDeviceFQDD
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.700.20
name: temperatureProbeTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.5
name: temperatureProbeStatus
chart_meta:
family: 'Hardware/Sensor/Temperature/Status'
description: Status of the temperature probe
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical_upper
5: critical_upper
6: non_recoverable_upper
7: non_critical_lower
8: critical_lower
9: non_recoverable_lower
10: failed
- OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.6
name: temperatureProbeReading
chart_meta:
family: 'Hardware/Sensor/Temperature/Value'
description: Reading of the temperature probe in degrees Celsius
unit: "Cel"
- OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.16
name: temperatureProbeDiscreteReading
chart_meta:
family: 'Hardware/Sensor/Temperature/DiscreteReading'
description: Discrete reading of the temperature probe
unit: "{reading}"
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.1
name: temperatureProbechassisIndex
- tag: temperature_probe_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.2
name: temperatureProbeIndex
- tag: temperature_probe_type
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.7
name: temperatureProbeType
mapping:
1: other
2: unknown
3: ambient_esm
16: discrete
- tag: temperature_probe_location_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.700.20.1.8
name: temperatureProbeLocationName
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.30
name: processorDeviceTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.5
name: processorDeviceStatus
chart_meta:
family: 'Hardware/Processor/Status'
description: Status of the processor device
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.11
name: processorDeviceMaximumSpeed
chart_meta:
family: 'Hardware/Processor/Speed/Maximum'
description: Maximum speed of the processor device in megahertz
unit: "MHz"
- OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.12
name: processorDeviceCurrentSpeed
chart_meta:
family: 'Hardware/Processor/Speed/Current'
description: Current speed of the processor device in megahertz
unit: "MHz"
- OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.14
name: processorDeviceVoltage
chart_meta:
family: 'Hardware/Processor/Voltage'
description: Voltage of the processor device in volts
unit: "V"
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.1
name: processorDevicechassisIndex
- tag: processor_device_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.2
name: processorDeviceIndex
- tag: processor_device_brand_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.23
name: processorDeviceBrandName
- tag: processor_device_fqdd
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.30.1.26
name: processorDeviceFQDD
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.32
name: processorDeviceStatusTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.5
name: processorDeviceStatusStatus
chart_meta:
family: 'Hardware/Processor/Device/Status/Status'
description: Status of the processor device status
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.6
name: processorDeviceStatusReading
chart_meta:
family: 'Hardware/Processor/Device/Status/Reading'
description: Reading of the processor device status
unit: "{reading}"
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.1
name: processorDeviceStatusChassisIndex
- tag: processor_device_status_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.2
name: processorDeviceStatusIndex
- tag: processor_device_status_location_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.32.1.7
name: processorDeviceStatusLocationName
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.50
name: memoryDeviceTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.5
name: memoryDeviceStatus
chart_meta:
family: 'Hardware/Memory/Status'
description: Status of the memory device
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
metric_tags:
- tag: device_type
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.7
name: memoryDeviceType
- tag: device_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.2
name: memoryDeviceIndex
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.1
name: memoryDevicechassisIndex
- tag: device_type
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.1100.50.1.7
name: memoryDeviceType
mapping:
1: other
2: unknown
3: dram
4: edram
5: vram
6: sram
7: ram
8: rom
9: flash
10: eeprom
11: feprom
12: eprom
13: cdram
14: 3dram
15: sdram
16: sgram
17: rdram
18: ddr
19: ddr2
20: ddr2_fbdimm
24: ddr3
25: fbd2
26: ddr4
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.4.2000.10
name: fruTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.3
name: fruInformationStatus
chart_meta:
family: 'Hardware/FRU/Status'
description: Status of the FRU information
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.1
name: fruChassisIndex
- tag: fru_index
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.2
name: fruIndex
- tag: fru_fqdd
symbol:
OID: 1.3.6.1.4.1.674.10892.5.4.2000.10.1.12
name: fruFQDD
- MIB: IDRAC-MIB-SMIv2
table:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1
name: virtualDiskTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4
name: virtualDiskState
chart_meta:
family: 'System/Disk/Virtual/State'
description: State of the virtual disk
unit: "{status}"
mapping:
1: unknown
2: online
3: failed
4: degraded
- OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6
name: virtualDiskSizeInMB
scale_factor: 1048576
chart_meta:
family: 'System/Disk/Virtual/Size'
description: Size of the virtual disk in megabytes
unit: "By"
- OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20
name: virtualDiskComponentStatus
chart_meta:
family: 'System/Disk/Virtual/ComponentStatus'
description: Component status of the virtual disk
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.37
name: virtualDiskT10PIStatus
chart_meta:
family: 'System/Disk/Virtual/T10PIStatus'
description: T10 PI status of the virtual disk
unit: "{status}"
mapping:
1: other
2: enabled
3: disabled
metric_tags:
- tag: virtual_disk_number
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1
name: virtualDiskNumber
- tag: virtual_disk_name
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.2
name: virtualDiskName
- tag: virtual_disk_fqdd
symbol:
OID: 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.35
name: virtualDiskFQDD
- MIB: DELL-RAC-MIB
symbol:
OID: 1.3.6.1.4.1.674.10892.2.3.1.9.0
name: drsCMCCurrStatus
chart_meta:
family: 'Hardware/CMC/Status'
description: CMC health status being monitored by the chassis management card
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- MIB: DELL-RAC-MIB
symbol:
OID: 1.3.6.1.4.1.674.10892.2.3.1.1.0
name: drsGlobalCurrStatus
chart_meta:
family: 'System/Global/Status'
description: Overall chassis status being monitored by the chassis management card
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- MIB: DELL-RAC-MIB
symbol:
OID: 1.3.6.1.4.1.674.10892.2.3.1.5.0
name: drsPowerCurrStatus
chart_meta:
family: 'Hardware/Power/Status'
description: Power subsystem health status being monitored by the chassis management card
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- MIB: DELL-RAC-MIB
symbol:
OID: 1.3.6.1.4.1.674.10892.2.3.1.4.0
name: drsRedCurrStatus
chart_meta:
family: 'System/Redundancy/Status'
description: Redundancy status being monitored by the chassis management card
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- MIB: DELL-RAC-MIB
symbol:
OID: 1.3.6.1.4.1.674.10892.2.2.1.0
name: drsGlobalSystemStatus
chart_meta:
family: 'System/Global/SystemStatus'
description: Overall chassis status being monitored by the chassis management card
unit: "{status}"
mapping:
1: other
2: unknown
3: ok
4: non_critical
5: critical
6: non_recoverable
- MIB: DELL-RAC-MIB
table:
OID: 1.3.6.1.4.1.674.10892.2.4.1
name: drsCMCPowerTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.2.4.1.1.13
name: drsWattsReading
chart_meta:
family: 'Hardware/Power/Usage'
description: Instantaneous chassis power usage in watts
unit: "W"
- OID: 1.3.6.1.4.1.674.10892.2.4.1.1.14
name: drsAmpsReading
chart_meta:
family: 'Hardware/Power/Current'
description: Instantaneous chassis current usage in amperes
unit: "A"
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.2.4.1.1.1
name: drsChassisIndex
- tag: drs_psu_index
symbol:
OID: 1.3.6.1.4.1.674.10892.2.4.2.1.2
name: drsPSUIndex
- MIB: DELL-RAC-MIB
metric_type: monotonic_count
table:
OID: 1.3.6.1.4.1.674.10892.2.4.1
name: drsCMCPowerTable
symbols:
- OID: 1.3.6.1.4.1.674.10892.2.4.1.1.6
name: drsKWhCumulative
chart_meta:
family: 'Hardware/Power/Energy/Cumulative'
description: Cumulative chassis power usage in kilowatt hours since last reset
unit: "kWh"
metric_tags:
- tag: chassis_index
symbol:
OID: 1.3.6.1.4.1.674.10892.2.4.1.1.1
name: drsChassisIndex
- tag: drs_psu_index
symbol:
OID: 1.3.6.1.4.1.674.10892.2.4.2.1.2
name: drsPSUIndex