File: //lib/netdata/conf.d/health.d/storcli.conf
# you can disable an alarm notification by setting the 'to' line to: silent
# Controllers
template: storcli_controller_health_status
on: storcli.controller_health_status
class: Errors
type: System
component: RAID
lookup: average -1m unaligned percentage of healthy
units: %
every: 10s
crit: $this < 100
delay: down 5m multiplier 2 max 10m
summary: RAID controller ${label:controller_number} health
info: RAID controller ${label:controller_number} is unhealthy
to: sysadmin
template: storcli_controller_bbu_status
on: storcli.controller_bbu_status
class: Errors
type: System
component: RAID
lookup: average -1m unaligned percentage of healthy,na
units: %
every: 10s
crit: $this < 100
delay: down 5m multiplier 2 max 10m
summary: RAID controller ${label:controller_number} BBU health
info: RAID controller ${label:controller_number} BBU is unhealthy
to: sysadmin
# Physical Drives
template: storcli_phys_drive_errors
on: storcli.phys_drive_errors
class: Errors
type: System
component: RAID
lookup: sum -10s
units: errors
every: 10s
warn: $this > 0
delay: up 1m down 5m multiplier 2 max 10m
summary: RAID PD c${label:controller_number}/e${label:enclosure_number}/s${label:slot_number} errors
info: RAID physical drive c${label:controller_number}/e${label:enclosure_number}/s${label:slot_number} errors
to: sysadmin
template: storcli_phys_drive_predictive_failures
on: storcli.phys_drive_predictive_failures
class: Errors
type: System
component: RAID
lookup: sum -10s
units: failures
every: 10s
warn: $this > 0
delay: up 1m down 5m multiplier 2 max 10m
summary: RAID PD c${label:controller_number}/e${label:enclosure_number}/s${label:slot_number} predictive failures
info: RAID physical drive c${label:controller_number}/e${label:enclosure_number}/s${label:slot_number} predictive failures
to: sysadmin