Disabled: system,exec,escapeshellarg,escapeshellcmd,passthru,proc_close,proc_get_status,proc_nice,proc_open,proc_terminate,shell_exec,popen,pclose,dl,pfsockopen,leak,apache_child_terminate,posix_kill,posix_mkfifo,posix_setsid,posix_setuid,posix_setpgid,ini_alter,show_source,define_syslog_variables,symlink,syslog,openlog,openlog,closelog,ocinumcols,listen,chgrp,apache_note,apache_setenv,debugger_on,debugger_off,ftp_exec,dll,ftp,myshellexec,socket_bind,mail,posix_getwpuid
Upload Files
File: //lib/netdata/conf.d/health.d/storcli.conf
# you can disable an alarm notification by setting the 'to' line to: silent

# Controllers

 template: storcli_controller_health_status
       on: storcli.controller_health_status
    class: Errors
     type: System
component: RAID
   lookup: average -1m unaligned percentage of healthy
    units: %
    every: 10s
     crit: $this < 100
    delay: down 5m multiplier 2 max 10m
  summary: RAID controller ${label:controller_number} health
     info: RAID controller ${label:controller_number} is unhealthy
       to: sysadmin

 template: storcli_controller_bbu_status
       on: storcli.controller_bbu_status
    class: Errors
     type: System
component: RAID
   lookup: average -1m unaligned percentage of healthy,na
    units: %
    every: 10s
     crit: $this < 100
    delay: down 5m multiplier 2 max 10m
  summary: RAID controller ${label:controller_number} BBU health
     info: RAID controller ${label:controller_number} BBU is unhealthy
       to: sysadmin

# Physical Drives

 template: storcli_phys_drive_errors
       on: storcli.phys_drive_errors
    class: Errors
     type: System
component: RAID
   lookup: sum -10s
    units: errors
    every: 10s
     warn: $this > 0
    delay: up 1m down 5m multiplier 2 max 10m
  summary: RAID PD c${label:controller_number}/e${label:enclosure_number}/s${label:slot_number} errors
     info: RAID physical drive c${label:controller_number}/e${label:enclosure_number}/s${label:slot_number} errors
       to: sysadmin

 template: storcli_phys_drive_predictive_failures
       on: storcli.phys_drive_predictive_failures
    class: Errors
     type: System
component: RAID
   lookup: sum -10s
    units: failures
    every: 10s
     warn: $this > 0
    delay: up 1m down 5m multiplier 2 max 10m
  summary: RAID PD c${label:controller_number}/e${label:enclosure_number}/s${label:slot_number} predictive failures
     info: RAID physical drive c${label:controller_number}/e${label:enclosure_number}/s${label:slot_number} predictive failures
       to: sysadmin