File: //lib/netdata/conf.d/health.d/processes.conf
# you can disable an alarm notification by setting the 'to' line to: silent
alarm: active_processes
on: system.active_processes
class: Workload
type: System
component: Processes
calc: $active * 100 / $pidmax
units: %
every: 5s
warn: $this > (($status >= $WARNING) ? (85) : (90))
crit: $this > (($status == $CRITICAL) ? (90) : (95))
delay: down 5m multiplier 1.5 max 1h
summary: System PIDs utilization
info: System process IDs (PID) space utilization
to: sysadmin