File: //lib/netdata/conf.d/go.d/snmp.profiles/default/hpe-bladesystem-enclosure.yaml
extends:
- _std-if-mib.yaml
- _std-ucd-mib.yaml
- _hp.yaml
- _hp-base.yaml
sysobjectid:
- 1.3.6.1.4.1.11.5.7.1.2
# https://mibbrowser.online/mibdb_search.php?mib=CPQRACK-MIB
# https://github.com/DanielleHuisman/observium-community-edition/blob/main/mibs/hp/CPQRACK-MIB
metrics:
- MIB: CPQRACK-MIB
table:
name: cpqRackCommonEnclosureTempTable
OID: 1.3.6.1.4.1.232.22.2.3.1.2
symbols:
- name: cpqRackCommonEnclosureTempCurrent
OID: 1.3.6.1.4.1.232.22.2.3.1.2.1.6
chart_meta:
description: This is the current temperature sensor reading in degrees celsius
family: 'Hardware/Sensor/Temperature/Value'
unit: "Cel"
- OID: 1.3.6.1.4.1.232.22.2.3.1.2.1.8
name: cpqRackCommonEnclosureTempCondition
chart_meta:
description: The Temperature sensor condition
family: 'Hardware/Sensor/Temperature/Status'
unit: "{status}"
mapping:
1: other
2: ok
3: degraded
4: failed
metric_tags:
- tag: cpq_rack_common_enclosure_temp_rack
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.2.1.1
name: cpqRackCommonEnclosureTempRack
- tag: cpq_rack_common_enclosure_temp_chassis
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.2.1.2
name: cpqRackCommonEnclosureTempChassis
- tag: cpq_rack_common_enclosure_temp_sensor_index
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.2.1.3
name: cpqRackCommonEnclosureTempSensorIndex
- tag: cpq_rack_common_enclosure_temp_sensor_enclosure_name
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.2.1.4
name: cpqRackCommonEnclosureTempSensorEnclosureName
- tag: cpq_rack_common_enclosure_temp_location
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.2.1.5
name: cpqRackCommonEnclosureTempLocation
- tag: cpq_rack_common_enclosure_temp_type
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.2.1.9
name: cpqRackCommonEnclosureTempType
mapping:
1: other
5: blowout
9: caution
15: critical
- MIB: CPQRACK-MIB
table:
name: cpqRackCommonEnclosureFanTable
OID: 1.3.6.1.4.1.232.22.2.3.1.3
symbols:
- OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.8
name: cpqRackCommonEnclosureFanPresent
chart_meta:
description: This specifies if the fan described is present in the system
family: 'Hardware/Fan/Presence/Status'
unit: "{status}"
mapping:
1: other
2: absent
3: present
- OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.9
name: cpqRackCommonEnclosureFanRedundant
chart_meta:
description: This specifies if the fan is in a redundant configuration
family: 'Hardware/Fan/Redundancy/Status'
unit: "{status}"
mapping:
1: other
2: notRedundant
3: redundant
- OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.11
name: cpqRackCommonEnclosureFanCondition
chart_meta:
description: The condition of the fan
family: 'Hardware/Fan/Status'
unit: "{status}"
mapping:
1: other
2: ok
3: degraded
4: failed
metric_tags:
- tag: cpq_rack_common_enclosure_fan_rack
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.1
name: cpqRackCommonEnclosureFanRack
- tag: cpq_rack_common_enclosure_fan_chassis
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.2
name: cpqRackCommonEnclosureFanChassis
- tag: cpq_rack_common_enclosure_fan_index
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.3
name: cpqRackCommonEnclosureFanIndex
- tag: _cpq_rack_common_enclosure_fan_location
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.5
name: cpqRackCommonEnclosureFanLocation
- tag: _cpq_rack_common_enclosure_fan_part_number
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.6
name: cpqRackCommonEnclosureFanPartNumber
- tag: _cpq_rack_common_enclosure_fan_spare_part_number
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.7
name: cpqRackCommonEnclosureFanSparePartNumber
- tag: _cpq_rack_common_enclosure_fan_redundant_group_id
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.10
name: cpqRackCommonEnclosureFanRedundantGroupId
- tag: _cpq_rack_common_enclosure_fan_enclosure_serial_num
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.3.1.12
name: cpqRackCommonEnclosureFanEnclosureSerialNum
- MIB: CPQRACK-MIB
table:
name: cpqRackCommonEnclosureFuseTable
OID: 1.3.6.1.4.1.232.22.2.3.1.4
symbols:
- OID: 1.3.6.1.4.1.232.22.2.3.1.4.1.6
name: cpqRackCommonEnclosureFusePresent
chart_meta:
description: This specifies if the fuse described is present in the system
family: 'Hardware/Fuse/Presence/Status'
unit: "{status}"
mapping:
1: other
2: absent
3: present
- OID: 1.3.6.1.4.1.232.22.2.3.1.4.1.7
name: cpqRackCommonEnclosureFuseCondition
chart_meta:
description: The condition of the fuse
family: 'Hardware/Fuse/Status'
unit: "{status}"
mapping:
1: other
2: ok
4: failed
metric_tags:
- tag: cpq_rack_common_enclosure_fuse_rack
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.4.1.1
name: cpqRackCommonEnclosureFuseRack
- tag: cpq_rack_common_enclosure_fuse_chassis
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.4.1.2
name: cpqRackCommonEnclosureFuseChassis
- tag: cpq_rack_common_enclosure_fuse_index
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.4.1.3
name: cpqRackCommonEnclosureFuseIndex
- tag: cpq_rack_common_enclosure_fuse_enclosure_name
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.4.1.4
name: cpqRackCommonEnclosureFuseEnclosureName
- tag: cpq_rack_common_enclosure_fuse_location
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.4.1.5
name: cpqRackCommonEnclosureFuseLocation
- MIB: CPQRACK-MIB
table:
name: cpqRackCommonEnclosureManagerTable
OID: 1.3.6.1.4.1.232.22.2.3.1.6
symbols:
- OID: 1.3.6.1.4.1.232.22.2.3.1.6.1.9
name: cpqRackCommonEnclosureManagerRole
chart_meta:
description: This specifies the current role of the manager
family: 'Hardware/EnclosureManager/Role/Status'
unit: "{status}"
mapping:
1: standby
2: active
- OID: 1.3.6.1.4.1.232.22.2.3.1.6.1.10
name: cpqRackCommonEnclosureManagerPresent
chart_meta:
description: This specifies if the manager described is present in the system
family: 'Hardware/EnclosureManager/Presence/Status'
unit: "{status}"
mapping:
1: other
2: absent
3: present
- OID: 1.3.6.1.4.1.232.22.2.3.1.6.1.11
name: cpqRackCommonEnclosureManagerRedundant
chart_meta:
description: This specifies if the manager is in a redundant configuration
family: 'Hardware/EnclosureManager/Redundancy/Status'
unit: "{status}"
mapping:
1: other
2: notRedundant
3: redundant
- OID: 1.3.6.1.4.1.232.22.2.3.1.6.1.12
name: cpqRackCommonEnclosureManagerCondition
chart_meta:
description: The condition of the manager
family: 'Hardware/EnclosureManager/Status'
unit: "{status}"
mapping:
1: other
2: ok
3: degraded
4: failed
metric_tags:
- tag: cpq_rack_common_enclosure_manager_enclosure_rack
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.6.1.1
name: cpqRackCommonEnclosureManagerRack
- tag: cpq_rack_common_enclosure_manager_enclosure_chassis
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.6.1.2
name: cpqRackCommonEnclosureManagerChassis
- tag: cpq_rack_common_enclosure_manager_enclosure_index
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.6.1.3
name: cpqRackCommonEnclosureManagerIndex
- tag: _cpq_rack_common_enclosure_manager_enclosure_name
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.6.1.4
name: cpqRackCommonEnclosureManagerEnclosureName
- tag: _cpq_rack_common_enclosure_manager_location
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.6.1.5
name: cpqRackCommonEnclosureManagerLocation
- tag: _cpq_rack_common_enclosure_manager_part_number
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.6.1.6
name: cpqRackCommonEnclosureManagerPartNumber
- tag: _cpq_rack_common_enclosure_manager_spare_part_number
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.6.1.7
name: cpqRackCommonEnclosureManagerSparePartNumber
- tag: _cpq_rack_common_enclosure_manager_serial_num
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.1.6.1.8
name: cpqRackCommonEnclosureManagerSerialNum
- MIB: CPQRACK-MIB
table:
name: cpqRackPowerEnclosureTable
OID: 1.3.6.1.4.1.232.22.2.3.3.1
symbols:
- OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.5
name: cpqRackPowerEnclosureRedundant
chart_meta:
description: This indicates if the power supply enclosure is in a redundant state
family: 'Hardware/PowerEnclosure/Redundancy/Status'
unit: "{status}"
mapping:
1: other
2: notRedundant
3: redundant
- OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.6
name: cpqRackPowerEnclosureLoadBalanced
chart_meta:
description: This indicates if the power supply enclosure is in a load balanced state
family: 'Hardware/PowerEnclosure/LoadBalance/Status'
unit: "{status}"
mapping:
1: other
2: notLoadBalanced
3: loadBalanced
- OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.10
name: cpqRackPowerEnclosureBladeAutopoweron
chart_meta:
description: This indicates current condition of the power enclosure
family: 'Hardware/PowerEnclosure/AutoPowerOn/Status'
unit: "{status}"
mapping:
1: other
2: disabled
3: enabled
- OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.9
name: cpqRackPowerEnclosureCondition
chart_meta:
description: This indicates current condition of the power enclosure
family: 'Hardware/PowerEnclosure/Status'
unit: "{status}"
mapping:
1: other
2: ok
3: degraded
metric_tags:
- tag: cpq_rack_power_enclosure_rack
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.1
name: cpqRackPowerEnclosureRack
- tag: cpq_rack_power_enclosure_index
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.2
name: cpqRackPowerEnclosureRack
- tag: _cpq_rack_power_enclosure_name
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.3
name: cpqRackPowerEnclosureName
- tag: _cpq_rack_power_enclosure_mgmt_board_serial_num
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.4
name: cpqRackPowerEnclosureMgmtBoardSerialNum
- tag: cpq_rack_power_enclosure_input_pwr_type
symbol:
OID: 1.3.6.1.4.1.232.22.2.3.3.1.1.7
name: cpqRackPowerEnclosureInputPwrType
mapping:
1: other
2: single_phase
3: three_phase
4: direct_current
- MIB: CPQRACK-MIB
table:
name: cpqRackServerBladeTable
OID: 1.3.6.1.4.1.232.22.2.4.1.1
symbols:
- name: cpqRackServerBladeFaultMajor
OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.22
chart_meta:
description: The major fault code of the blade fault reported by the enclosure manager
family: 'Hardware/ServerBlade/Fault/Major'
unit: "{fault_code}"
- name: cpqRackServerBladeFaultMinor
OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.23
chart_meta:
description: The minor fault code of the blade fault reported by the enclosure manager
family: 'Hardware/ServerBlade/Fault/Minor'
unit: "{fault_code}"
- OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.12
name: cpqRackServerBladePresent
chart_meta:
description: This specifies if the server blade described is present in the enclosure
family: 'Hardware/ServerBlade/Presence/Status'
unit: "{status}"
mapping:
1: other
2: absent
3: present
- OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.13
name: cpqRackServerBladeHasFuses
chart_meta:
description: This specifies if the server blade contains fuses
family: 'Hardware/ServerBlade/Fuse/Status'
unit: "{status}"
mapping:
1: false
2: true
- OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.35
name: cpqRackServerBladePOSTStatus
chart_meta:
description: Blade server power-on self test (POST) status
family: 'Hardware/ServerBlade/POST/Status'
unit: "{status}"
mapping:
1: other
2: started
3: completed
4: failed
- OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.21
name: cpqRackServerBladeStatus
chart_meta:
description: The health status of the blade
family: 'Hardware/ServerBlade/Status'
unit: "{status}"
mapping:
1: other
2: ok
3: degraded
4: failed
- OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.25
name: cpqRackServerBladePowered
chart_meta:
description: The power state of the blade
family: 'Hardware/ServerBlade/Power/Status'
unit: "{status}"
mapping:
1: other
2: on
3: off
4: powerStagedOff
5: reboot
- OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.26
name: cpqRackServerBladeUIDState
chart_meta:
description: The Unit Identifier LED status
family: 'Hardware/ServerBlade/UID/Status'
unit: "{status}"
mapping:
1: other
2: none
3: ledOn
4: ledOff
metric_tags:
- tag: cpq_rack_server_blade_rack
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.1
name: cpqRackServerBladeRack
- tag: cpq_rack_server_blade_chassis
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.2
name: cpqRackServerBladeChassis
- tag: cpq_rack_server_blade_index
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.3
name: cpqRackServerBladeIndex
- tag: _cpq_rack_server_blade_name
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.4
name: cpqRackServerBladeName
- tag: _cpq_rack_server_blade_part_number
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.6
name: cpqRackServerBladePartNumber
- tag: _cpq_rack_server_blade_spare_part_number
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.7
name: cpqRackServerBladeSparePartNumber
- tag: _cpq_rack_server_blade_position
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.8
name: cpqRackServerBladePosition
- tag: _cpq_rack_server_blade_serial_num
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.16
name: cpqRackServerBladeSerialNum
- tag: _cpq_rack_server_blade_product_id
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.17
name: cpqRackServerBladeProductId
- tag: _cpq_rack_server_blade_uid
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.1.1.1.18
name: cpqRackServerBladeUid
- MIB: CPQRACK-MIB
table:
name: cpqRackServerTempSensorTable
OID: 1.3.6.1.4.1.232.22.2.4.3.1
symbols:
- name: cpqRackServerTempSensorCurrent
OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.8
chart_meta:
description: This is the current temperature sensor reading in degrees celsius
family: 'Hardware/ServerBlade/Temperature/Value'
unit: "Cel"
- OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.10
name: cpqRackServerTempSensorCondition
chart_meta:
description: The Temperature sensor condition
family: 'Hardware/ServerBlade/Temperature/Status'
unit: "{status}"
mapping:
1: other
2: ok
3: degraded
4: failed
metric_tags:
- tag: cpq_rack_server_temp_sensor_rack
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.1
name: cpqRackServerTempSensorRack
- tag: cpq_rack_server_temp_sensor_chassis
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.2
name: cpqRackServerTempSensorChassis
- tag: cpq_rack_server_temp_sensor_index
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.3
name: cpqRackServerTempSensorIndex
- tag: _cpq_rack_server_temp_sensor_name
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.4
name: cpqRackServerTempSensorName
- tag: _cpq_rack_server_temp_sensor_location
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.7
name: cpqRackServerTempSensorLocation
- tag: cpq_rack_server_temp_sensor_type
symbol:
OID: 1.3.6.1.4.1.232.22.2.4.3.1.1.11
name: cpqRackServerTempSensorType
mapping:
1: other
5: blowout
9: caution
15: critical
- MIB: CPQRACK-MIB
table:
name: cpqRackPowerSupplyTable
OID: 1.3.6.1.4.1.232.22.2.5.1.1
symbols:
- name: cpqRackPowerSupplyCurPwrOutput
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.10
chart_meta:
description: The current power output of the power supply in watts
family: 'Hardware/Power/Output/Value'
unit: "W"
- name: cpqRackPowerSupplyIntakeTemp
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.12
chart_meta:
description: The current air temperature at the intake of the power supply in degrees celsius
family: 'Hardware/Power/Temperature/Intake'
unit: "Cel"
- name: cpqRackPowerSupplyExhaustTemp
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.13
chart_meta:
description: The current air temperature at the exhaust of the power supply in degrees celsius
family: 'Hardware/Power/Temperature/Exhaust'
unit: "Cel"
- OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.16
name: cpqRackPowerSupplyPresent
chart_meta:
description: This specifies if the power supply described is present in the enclosure
family: 'Hardware/Power/Presence/Status'
unit: "{status}"
mapping:
1: other
2: absent
3: present
- OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.14
name: cpqRackPowerSupplyStatus
chart_meta:
description: The status of the power supply
family: 'Hardware/Power/Status'
unit: "{status}"
mapping:
1: noError
2: generalFailure
3: bistFailure
4: fanFailure
5: tempFailure
6: interlockOpen
7: epromFailed
8: vrefFailed
9: dacFailed
10: ramTestFailed
11: voltageChannelFailed
12: orringdiodeFailed
13: brownOut
14: giveupOnStartup
15: nvramInvalid
16: calibrationTableInvalid
- OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.15
name: cpqRackPowerSupplyInputLineStatus
chart_meta:
description: The status of line input power
family: 'Hardware/Power/Input/Status'
unit: "{status}"
mapping:
1: noError
2: lineOverVoltage
3: lineUnderVoltage
4: lineHit
5: brownOut
6: linePowerLoss
- OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.17
name: cpqRackPowerSupplyCondition
chart_meta:
description: The condition of the power supply
family: 'Hardware/Power/Condition/Status'
unit: "{status}"
mapping:
1: other
2: ok
3: degraded
4: failed
metric_tags:
- tag: cpq_rack_power_supply_enclosure_rack
symbol:
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.1
name: cpqRackPowerSupplyEnclosureRack
- tag: cpq_rack_power_supply_enclosure_chassis
symbol:
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.2
name: cpqRackPowerSupplyEnclosureChassis
- tag: cpq_rack_power_supply_enclosure_index
symbol:
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.3
name: cpqRackPowerSupplyEnclosureIndex
- tag: _cpq_rack_power_supply_enclosure_name
symbol:
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.4
name: cpqRackPowerSupplyEnclosureName
- tag: _cpq_rack_power_supply_serial_num
symbol:
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.5
name: cpqRackPowerSupplySerialNum
- tag: _cpq_rack_power_supply_part_number
symbol:
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.6
name: cpqRackPowerSupplyPartNumber
- tag: _cpq_rack_power_supply_spare_part_number
symbol:
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.7
name: cpqRackPowerSupplySparePartNumber
- tag: _cpq_rack_power_supply_fw_rev
symbol:
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.8
name: cpqRackPowerSupplyFWRev
- tag: _cpq_rack_power_supply_max_pwr_output
symbol:
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.9
name: cpqRackPowerSupplyMaxPwrOutput
- tag: _cpq_rack_power_supply_enclosure_serial_num
symbol:
OID: 1.3.6.1.4.1.232.22.2.5.1.1.1.18
name: cpqRackPowerSupplyEnclosureSerialNum